EXO12CH | 12 V | DC | DC | Ex Approved | Hazardous locations

0914 237 179

EXO12CH | 12 V | DC | DC | Ex Approved | Hazardous locations

  • 3
  • Delcon - Phần lan
  • EXO12CH
  • Liên hệ

Tư vấn ngay: 0914 237 179 - sale11@ltdautomation.com.vn

Datasheet

EXO-12CH-1.pdf

3D files

relay_exo_xxxx_28.zip

Qualifications

  • CE
  • cULus Listed
  • RoHS
  • EAC

Main data

Nominal load voltage 60 V DC
Nominal input voltage 12 V DC
Rated load current 3 A
MTTF (MIL-HDBK-217F) 125,6 years

Control circuit

Switch-on voltage 8 V DC
Switch-off voltage 7 V DC
Power consumption 126 mW

Load circuit

Load current range 3 A
Load voltage range 60 V DC
Inrush current 15 A, 10 ms
Max. Inductive load, L/R 0,5 ms (60 V, 3 A)
Max. Inductive load, L/R 5 ms (24 V, 2 A)
Leakage current 1 mA
Voltage drop 0,5 V
Switch-on time 0,3 ms
Switch-off time 0,3 ms

Insulation

Insulation method Pulse transformer (an unique feature for Delcon relay compared to opto)
Test voltage input/output 4600 V ACrms / 1 s
Overvoltage category III
Pollution degree 2
Air/creepage distance I/O 8 mm

General data

Conductor size, screw terminal 2,5 mm2
Conductor size, spring terminal 0,75 - 2,5 mm2
Operating temperature -25 °C to +70 °C
Weight 40 g
Housing material flammability UL 94 V-0
Package size 10, 50 and 100
Sản phẩm
Zalo
Hotline